A Detector in Splunk Observability Cloud evaluates SignalFlow alert rules on streaming data and emits events when conditions trigger or clear.
You can create a standalone detector from scratch, clone an existing built-in detector, or convert any chart directly into a detector. Every detector rule specifies an alert signal, an alert condition, one of five severity tiers (Critical, Major, Minor, Warning, Info), custom alert message templates, and notification recipients such as Slack, PagerDuty, Splunk On-Call, Opsgenie, Microsoft Teams, Jira, ServiceNow, Email, or Webhooks.
Users can also subscribe directly to an existing detector to receive notifications without duplicating its SignalFlow logic, keeping alert definitions centralized and maintainable.
Critical -> Immediate page (PagerDuty / Splunk On-Call)
Major -> High-priority incident channel (Slack / Opsgenie)
Minor -> Engineering triage queue (Jira / Email)
Warning -> Early degradation notice
Info -> Informational tracking / audit